Abstract
In the UK, there is mounting evidence that the measured in situ performance of the building fabric in new build dwellings can be greater than that predicted, resulting in a significant building fabric ‘performance gap’. This paper presents the coheating test results from 25 new build dwellings built to Part L1A 2006 or better. Whilst the total number of dwellings reported here is small, the results suggest that a substantial ‘performance gap’ can exist between the predicted and measured performance of the building fabric, with the measured whole building U-value being just over 1.6 times greater than that predicted. This is likely to have significant implications in terms of the energy use and CO2 emissions attributable to these dwellings in-use.
Official URL
More Information
Identification Number: | https://doi.org/10.1177/0143624415570344 |
---|---|
Status: | Published |
Refereed: | Yes |
Date Deposited: | 27 Jan 2015 16:11 |
Last Modified: | 11 Jul 2024 10:40 |
Item Type: | Article |
Download
Note: this is the author's final manuscript and may differ from the published version which should be used for citation purposes. (Converted to PDF)
| Preview