Abstract
This paper presents the methodology, along with some of the initial findings and observations from tests performed on two dwellings, of differing construction and form, in which a coheating test was performed using the dwelling's central heating system; this method is referred to as integrated coheating. Data obtained during the integrated coheating tests using a dwelling's heating system have been compared with data obtained during electric coheating of the same dwelling. In one instance, integrated coheating test data from one dwelling was compared to a similar adjoining control dwelling that was simultaneously subject to an electric coheating test. The results show a good agreement between the heat loss coefficients (HLC) obtained using a dwelling's own heating system and those obtained through electrical coheating. Initial analysis suggests the HLC estimate obtained from integrated coheating is likely to be more representative of how a dwelling performs in-use. The findings question the appropriateness of comparing current steady-state HLC predictions to those derived from in-use monitoring data. Integrated coheating has the potential to provide a more cost-effective and informative indication of whole house heat loss than electric coheating, as it enables in situ quantification of both fabric and heating system performance.
Official URL
More Information
Status: | Published |
---|---|
Refereed: | Yes |
Publisher: | Atelier des Presses |
Uncontrolled Keywords: | Calibration, Domestic, Energy Performance, Thermal Modeling |
Date Deposited: | 11 Mar 2016 09:11 |
Last Modified: | 10 Jul 2024 19:19 |
Event Title: | SYSTEM SIMULATION IN BUILDINGS 2014 |
Item Type: | Conference or Workshop Item (Paper) |
Download
Note: this is the author's final manuscript and may differ from the published version which should be used for citation purposes.
License: Creative Commons Attribution
| Preview