Abstract
OBJECTIVES: The efficacy of transcutaneous electrical nerve stimulation (TENS) for pain relief has not been reliably established. Inconclusive findings could be due to inadequate TENS delivery and inappropriate outcome assessment. Electronic monitoring devices were used to determine patient compliance with a TENS intervention and outcome assessment protocol, to record pain scores before, during, and after TENS, and measure electrical output settings. METHODS: Patients with chronic back pain consented to use TENS daily for 2 weeks and to report pain scores before, during, and after 1-hour treatments. A ≥ 30% reduction in pain scores was used to classify participants as TENS responders. Electronic monitoring devices "TLOG" and "TSCORE" recorded time and duration of TENS use, electrical settings, and pain scores. RESULTS: Forty-two patients consented to participate. One of 35 (3%) patients adhered completely to the TENS use and pain score reporting protocol. Fourteen of 33 (42%) were TENS responders according to electronic pain score data. Analgesia onset occurred within 30 to 60 minutes for 13/14 (93%) responders. It was not possible to correlate TENS amplitude, frequency, or pulse width measurements with therapeutic response. DISCUSSION: Findings from TENS research studies depend on the timing of outcome assessment; pain should be recorded during stimulation. TENS device sophistication might be an issue and parameter restriction should be considered. Careful protocol design is required to improve adherence and monitoring is necessary to evaluate the validity of findings. This observational study provides objective evidence to support concerns about poor implementation fidelity in TENS research.
Official URL
More Information
Identification Number: | https://doi.org/10.1097/AJP.0b013e31828dc828 |
---|---|
Status: | Published |
Refereed: | Yes |
Publisher: | Lippincott, Williams & Wilkins |
Uncontrolled Keywords: | data collection, transcutaneous electrical nerve stimulation, pain measurement, electronic data capture, Humans, Back Pain, Pain Measurement, Transcutaneous Electric Nerve Stimulation, Patient Compliance, Time Factors, Adult, Aged, Aged, 80 and over, Middle Aged, Outcome Assessment (Health Care), Female, Male, Electrical Equipment and Supplies, Young Adult, Chronic Pain, Adult, Aged, Aged, 80 and over, Back Pain, Chronic Pain, Electrical Equipment and Supplies, Female, Humans, Male, Middle Aged, Outcome Assessment (Health Care), Pain Measurement, Patient Compliance, Time Factors, Transcutaneous Electric Nerve Stimulation, Young Adult, 1103 Clinical Sciences, 1109 Neurosciences, Anesthesiology, |
Depositing User (symplectic) | Deposited by Johnson, Mark |
Date Deposited: | 29 Mar 2017 15:18 |
Last Modified: | 11 Jul 2024 13:23 |
Item Type: | Article |
Download
Note: this is the author's final manuscript and may differ from the published version which should be used for citation purposes.
| Preview
Export Citation
Explore Further
Read more research from the author(s):